← Feature Explorer
FOW-ENV-099Medium
Open Burn / Open Detonation – Line A
Open Burn / Open Detonation – Line A: design, construction and commissioning within a defense energetics production facility.
Most Restrictive Requirement
40 CFR 264RCRA Subpart X permit conditions govern treatment of energetic waste.
Design Criteria
Illustrative values — confirm against the cited edition before design use.
Summary
- Discipline
- Explosives Safety
- Category
- Environmental
- Risk Level
- Medium
- Approval Authority
- EPA
- Standards Applied
- 10 across 7 families
- Verified Links
- 2 of 10 approved
- Common Equipment
- Thermal Oxidizer
Applicable Standards (10)
Explosives Safety
- DoDDESR 6055.09DraftDoD Explosives Safety Regulation (Volumes 1–8)
Process Safety
- OSHA29 CFR 1910.147ReviewedControl of Hazardous Energy (Lockout/Tagout)
- PEDEN 13480ApprovedMetallic Industrial Piping
- UFGSUFGS 43 41 00ApprovedProcess Tanks
Environmental
- EU2010/75/EUDraftIndustrial Emissions Directive (IED)
- EPA40 CFR 264 Subpart XDraftMiscellaneous Units — RCRA permits for OB/OD
- EPA40 CFR 264governsReviewedRCRA Hazardous Waste TSD Facilities
- EPA40 CFR 112DraftSpill Prevention, Control and Countermeasure
- UFCUFC 3-810-01NReviewedEnvironmental Engineering
- EPA40 CFR 265ReviewedInterim Status TSD Standards (OB/OD)
Governing Authorities
- LeadEPAFederal Environmental Regulator · Air permits, RCRA hazardous waste
Highest Risk Items
- Toxic solvent vapor exposureMediumAdministrative controls, periodic inspection and documented procedures.
- Air permit exceedanceMediumAdministrative controls, periodic inspection and documented procedures.
Known U.S. / European Conflicts (6)
DESR 6055.09↔UK ER 2014· Explosives separation distancesSignificant Difference
UK uses HSE separation tables by hazard type; apply the more restrictive distance per exposure and document both.
DESR 6055.09↔SprengG· Explosives licensing and storagePartial
German storage groups map loosely to HD; host-nation licensing is required in addition to DDESB site plan.
DESR 6055.09↔2. SprengV· Storage separation distancesPartial
Compare Lagergruppe distances to DESR QD; use larger value.
40 CFR 70↔2010/75/EU· Air emissions permittingPartial
IED requires BAT conclusions; Title V does not. Prepare BAT assessment for EU sites.
ASME B31.3↔EN 13480· Process pipingPartial
Partial alignment; supplemental U.S. testing or documentation required.
UFC 3-810-01N↔EN 1993· Exhaust stacksPartial
Partial alignment; supplemental U.S. testing or documentation required.