Risk
Risk Register
Severity × probability across all mapped compliance risks.
Risk Matrix
P1
P2
P3
P4
Critical
1
2
1
1
High
1
4
5
2
Medium
3
3
1
Low
1
Probability →
| Risk | Severity | P | Score | Mitigation |
|---|---|---|---|---|
| Accidental detonation during mixing | Critical | 4 | 80 | Remote operation, shielding per UFC 3-340-02, and explosives safety review prior to start-up. |
| Dust deflagration in collection system | Critical | 3 | 60 | Remote operation, shielding per UFC 3-340-02, and explosives safety review prior to start-up. |
| Procurement of non-ASME vessel | High | 4 | 60 | Engineering controls, third-party verification and AHJ acceptance testing. |
| Unapproved European Ex equipment installed | High | 4 | 60 | Engineering controls, third-party verification and AHJ acceptance testing. |
| Inadequate hazardous ventilation | High | 3 | 45 | Engineering controls, third-party verification and AHJ acceptance testing. |
| Incorrect area classification | High | 3 | 45 | Engineering controls, third-party verification and AHJ acceptance testing. |
| Static ignition of propellant dust | High | 3 | 45 | Engineering controls, third-party verification and AHJ acceptance testing. |
| Fire suppression response time inadequate | High | 3 | 45 | Engineering controls, third-party verification and AHJ acceptance testing. |
| Cyber intrusion on PLC network | High | 3 | 45 | Engineering controls, third-party verification and AHJ acceptance testing. |
| Schedule delay from submittal rejection | Medium | 4 | 40 | Administrative controls, periodic inspection and documented procedures. |
| Insufficient QD separation | Critical | 2 | 40 | Remote operation, shielding per UFC 3-340-02, and explosives safety review prior to start-up. |
| Extruder thermal runaway | Critical | 2 | 40 | Remote operation, shielding per UFC 3-340-02, and explosives safety review prior to start-up. |
| Arc flash at switchgear | High | 2 | 30 | Engineering controls, third-party verification and AHJ acceptance testing. |
| Loss of fire water supply | High | 2 | 30 | Engineering controls, third-party verification and AHJ acceptance testing. |
| Toxic solvent vapor exposure | Medium | 3 | 30 | Administrative controls, periodic inspection and documented procedures. |
| SIS spurious trip impacting production | Medium | 3 | 30 | Administrative controls, periodic inspection and documented procedures. |
| Overpressure of pressure vessel | High | 2 | 30 | Engineering controls, third-party verification and AHJ acceptance testing. |
| Unauthorized access to energetic storage | High | 2 | 30 | Engineering controls, third-party verification and AHJ acceptance testing. |
| Hazardous waste permit violation | Medium | 3 | 30 | Administrative controls, periodic inspection and documented procedures. |
| Air permit exceedance | Medium | 2 | 20 | Administrative controls, periodic inspection and documented procedures. |
| Lightning strike in explosive area | Medium | 2 | 20 | Administrative controls, periodic inspection and documented procedures. |
| Crane load drop on energetics | Critical | 1 | 20 | Remote operation, shielding per UFC 3-340-02, and explosives safety review prior to start-up. |
| Generator failure during emergency | Medium | 2 | 20 | Administrative controls, periodic inspection and documented procedures. |
| Documentation not in English | Low | 4 | 20 | Track in submittal register and resolve during design review. |
| Blast door failure | High | 1 | 15 | Engineering controls, third-party verification and AHJ acceptance testing. |