← Equipment
Environmental · Compliance Report
Thermal Oxidizer
Thermal Oxidizer used in energetics production and support facilities.
Most Restrictive Requirement
40 CFR 68
Risk Management Program
Required Certifications
- EPA Performance Test
- NRTL Listing
- Air Permit Conformance
Typically Missing at Submittal
- EPA Performance Test
- DoD RMF ATO
Known Issues
- Metric conduit threads incompatible with NPT fittings
- Blast loading not evaluated per UFC 3-340-02
Required Standards (4)
- EPA40 CFR 68Risk Management Program
- EPA40 CFR 112Spill Prevention, Control and Countermeasure
- UFCUFC 3-810-01NEnvironmental Engineering
- EPA40 CFR 265Interim Status TSD Standards (OB/OD)
Approval Authorities
- Electrical Safety AuthorityElectrical AHJ
- Contracting OfficerProcurement Authority
Used in Features of Work
- Hazardous Ventilation – Line AHigh
- Hazardous Ventilation – Building 100High
- Dust Collection – Building 200High
- Dust CollectionHigh
- Open Burn / Open Detonation – Line AMedium
- Open Burn / Open Detonation – Building 100Medium
- Air Emissions Control – Building 200Medium
- Air Emissions ControlMedium
- Wastewater Treatment – Line AMedium
- Wastewater Treatment – Building 100Medium