Compliance Crosswalk
U.S. ↔ European Requirements
Where European-designed equipment and designs must be reconciled with U.S. codes before approval.
19
Similar
45
Partial
18
Significant Difference
Compatibility
Conflict level
| U.S. Requirement | European Requirement | Topic | Compatibility | Conflict | Resolution |
|---|---|---|---|---|---|
| NFPA 70 | IEC 60364 | Low-voltage installations | Partial | Medium | Partial alignment; supplemental U.S. testing or documentation required. |
| ASME BPVC VIII-1 | EN 13445 | Pressure vessel design | Partial | Medium | Partial alignment; supplemental U.S. testing or documentation required. |
| NEC Art. 500 | 2014/34/EU | Hazardous area equipment | Significant Difference | High | Fundamental differences; requires AHJ/NRTL review and likely redesign or re-certification. |
| AISC 360 | EN 1993 | Structural steel design | Similar | Low | Requirements broadly equivalent; document equivalency in design analysis. |
| NEC Art. 505 | IEC 60079-14 | Zone installations | Similar | Low | Requirements broadly equivalent; document equivalency in design analysis. |
| UFC 3-340-02 | EN 1991-1-7 | Accidental explosion loads | Significant Difference | High | Fundamental differences; requires AHJ/NRTL review and likely redesign or re-certification. |
| NFPA 68 | DIN EN 14491 | Dust explosion venting | Partial | Medium | Partial alignment; supplemental U.S. testing or documentation required. |
| NFPA 69 | DIN EN 14373 | Explosion suppression | Partial | Medium | Partial alignment; supplemental U.S. testing or documentation required. |
| NFPA 654 | VDI 2263 | Combustible dust | Partial | Medium | Partial alignment; supplemental U.S. testing or documentation required. |
| NFPA 13 | DIN EN 12845 | Sprinkler design | Significant Difference | High | Fundamental differences; requires AHJ/NRTL review and likely redesign or re-certification. |
| NFPA 72 | DIN EN 54 | Fire detection | Partial | Medium | Partial alignment; supplemental U.S. testing or documentation required. |
| NFPA 780 | DIN EN 62305 | Lightning protection | Partial | Medium | Partial alignment; supplemental U.S. testing or documentation required. |
| ASME B31.3 | EN 13480 | Process piping | Partial | Medium | Partial alignment; supplemental U.S. testing or documentation required. |
| IEC 61511 | DIN EN ISO 13849-1 | Safety control systems | Partial | Medium | Partial alignment; supplemental U.S. testing or documentation required. |
| 29 CFR 1910.119 | 1999/92/EC | Process safety / workplace explosion | Significant Difference | High | Fundamental differences; requires AHJ/NRTL review and likely redesign or re-certification. |
| NEC Art. 409 | IEC 61439 | Control panel assemblies | Partial | Medium | Partial alignment; supplemental U.S. testing or documentation required. |
| UL 508A | IEC 60204-1 | Industrial machinery electrical | Partial | Medium | Partial alignment; supplemental U.S. testing or documentation required. |
| IEEE 1584 | IEC 61482 | Arc flash | Significant Difference | High | Fundamental differences; requires AHJ/NRTL review and likely redesign or re-certification. |
| ACI 318 | EN 1992 | Concrete design | Similar | Low | Requirements broadly equivalent; document equivalency in design analysis. |
| ASCE 7 | EN 1990 | Load combinations | Partial | Low | Partial alignment; supplemental U.S. testing or documentation required. |
| UFC 3-310-04 | EN 1998 | Seismic design | Partial | Medium | Partial alignment; supplemental U.S. testing or documentation required. |
| ASME BPVC IX | EN ISO 15614 | Weld procedure qualification | Similar | Low | Requirements broadly equivalent; document equivalency in design analysis. |
| NEC Art. 250 | DIN VDE 0100 | Grounding and bonding | Partial | Medium | Partial alignment; supplemental U.S. testing or documentation required. |
| UFC 4-010-06 | IEC 62443 | OT cybersecurity | Partial | High | Partial alignment; supplemental U.S. testing or documentation required. |
| NFPA 77 | IEC TS 60079-32-1 | Static electricity | Similar | Low | Requirements broadly equivalent; document equivalency in design analysis. |
| NFPA 496 | IEC 60079-2 | Pressurized enclosures | Similar | Low | Requirements broadly equivalent; document equivalency in design analysis. |
| NFPA 101 | DIN EN 1838 | Egress and emergency lighting | Partial | Medium | Partial alignment; supplemental U.S. testing or documentation required. |
| NEC Art. 506 | IEC 60079-10-2 | Dust zone classification | Similar | Low | Requirements broadly equivalent; document equivalency in design analysis. |
| NFPA 20 | EN 12845 Pump Clause | Fire pumps | Significant Difference | High | Fundamental differences; requires AHJ/NRTL review and likely redesign or re-certification. |
| ASME Sec. VIII UG-125 | EN ISO 4126 | Pressure relief | Partial | Medium | Partial alignment; supplemental U.S. testing or documentation required. |
| UFC 4-020-01 | IEC 60079-14 | Motor efficiency | Partial | Medium | Partial alignment; supplemental U.S. testing or documentation required. |
| UFGS 21 13 18 | 2014/34/EU | Cable sizing | Partial | Low | Partial alignment; supplemental U.S. testing or documentation required. |
| UFGS 40 05 13 | DIN EN 1127-1 | Conduit systems | Significant Difference | High | Fundamental differences; requires AHJ/NRTL review and likely redesign or re-certification. |
| NFPA 70 | DIN EN ISO 13849-1 | Enclosure ratings | Similar | Low | Requirements broadly equivalent; document equivalency in design analysis. |
| NFPA 654 | EN 1993 | Emergency stop circuits | Partial | Medium | Partial alignment; supplemental U.S. testing or documentation required. |
| 29 CFR 1910.109 | VDI 3783 | Terminal marking | Partial | Low | Partial alignment; supplemental U.S. testing or documentation required. |
| 40 CFR 63 | EN 764-7 | Wire color coding | Significant Difference | High | Fundamental differences; requires AHJ/NRTL review and likely redesign or re-certification. |
| ASME PCC-2 | IEC 61511 | Voltage levels | Similar | Low | Requirements broadly equivalent; document equivalency in design analysis. |
| IEEE 142 | IEC 60079-14 | Transformer design | Partial | Medium | Partial alignment; supplemental U.S. testing or documentation required. |
| UFGS 22 05 00 | 2014/34/EU | Switchgear testing | Partial | Low | Partial alignment; supplemental U.S. testing or documentation required. |
| UFGS 33 11 00 | DIN EN 1127-1 | Instrument air | Significant Difference | High | Fundamental differences; requires AHJ/NRTL review and likely redesign or re-certification. |
| UFC 4-422-01 | DIN EN ISO 13849-1 | HVAC duct design | Similar | Low | Requirements broadly equivalent; document equivalency in design analysis. |
| UFC 3-810-01N | EN 1993 | Exhaust stacks | Partial | Medium | Partial alignment; supplemental U.S. testing or documentation required. |
| NFPA 2001 | VDI 3783 | Noise limits | Partial | Low | Partial alignment; supplemental U.S. testing or documentation required. |
| UFC 3-410-01 | EN 764-7 | Vibration | Significant Difference | High | Fundamental differences; requires AHJ/NRTL review and likely redesign or re-certification. |
| UFGS 13 34 19 | IEC 61511 | Fire doors | Similar | Low | Requirements broadly equivalent; document equivalency in design analysis. |
| UFGS 25 05 11 | IEC 60079-14 | Fire dampers | Partial | Medium | Partial alignment; supplemental U.S. testing or documentation required. |
| NFPA 68 | 2014/34/EU | Smoke control | Partial | Low | Partial alignment; supplemental U.S. testing or documentation required. |
| NFPA 101 | DIN EN 1127-1 | Water supply | Significant Difference | High | Fundamental differences; requires AHJ/NRTL review and likely redesign or re-certification. |
| NFPA 850 | DIN EN ISO 13849-1 | Hydrant spacing | Similar | Low | Requirements broadly equivalent; document equivalency in design analysis. |
| 40 CFR 68 | EN 1993 | Hazardous waste labeling | Partial | Medium | Partial alignment; supplemental U.S. testing or documentation required. |
| ASME B31.1 | VDI 3783 | Air quality | Partial | Low | Partial alignment; supplemental U.S. testing or documentation required. |
| NEC Art. 700 | EN 764-7 | Wastewater discharge | Significant Difference | High | Fundamental differences; requires AHJ/NRTL review and likely redesign or re-certification. |
| UFGS 08 34 63 | IEC 61511 | Crane design | Similar | Low | Requirements broadly equivalent; document equivalency in design analysis. |
| UFGS 28 31 76 | IEC 60079-14 | Lifting gear | Partial | Medium | Partial alignment; supplemental U.S. testing or documentation required. |
| UFGS 01 35 26 | 2014/34/EU | Ladders and platforms | Partial | Low | Partial alignment; supplemental U.S. testing or documentation required. |
| UFC 3-230-01 | DIN EN 1127-1 | Guarding | Significant Difference | High | Fundamental differences; requires AHJ/NRTL review and likely redesign or re-certification. |
| NFPA 497 | DIN EN ISO 13849-1 | Lockout tagout | Similar | Low | Requirements broadly equivalent; document equivalency in design analysis. |
| UFC 4-010-01 | EN 1993 | Confined space | Partial | Medium | Partial alignment; supplemental U.S. testing or documentation required. |
| UFC 3-550-01 | VDI 3783 | Battery rooms | Partial | Low | Partial alignment; supplemental U.S. testing or documentation required. |
| UFGS 26 05 00 | EN 764-7 | UPS systems | Significant Difference | High | Fundamental differences; requires AHJ/NRTL review and likely redesign or re-certification. |
| NFPA 400 | IEC 61511 | Generator testing | Similar | Low | Requirements broadly equivalent; document equivalency in design analysis. |
| NFPA 20 | IEC 60079-14 | Grounding grids | Partial | Medium | Partial alignment; supplemental U.S. testing or documentation required. |
| NFPA 496 | 2014/34/EU | Surge protection | Partial | Low | Partial alignment; supplemental U.S. testing or documentation required. |
| 29 CFR 1910.1000 | DIN EN 1127-1 | Cathodic protection | Significant Difference | High | Fundamental differences; requires AHJ/NRTL review and likely redesign or re-certification. |
| ASME BPVC VIII-1 | DIN EN ISO 13849-1 | Steel connections | Similar | Low | Requirements broadly equivalent; document equivalency in design analysis. |
| NEC Art. 506 | EN 1993 | Anchor bolts | Partial | Medium | Partial alignment; supplemental U.S. testing or documentation required. |
| UFGS 03 30 00 | VDI 3783 | Concrete testing | Partial | Low | Partial alignment; supplemental U.S. testing or documentation required. |
| UFGS 26 13 00 | EN 764-7 | Welding inspection | Significant Difference | High | Fundamental differences; requires AHJ/NRTL review and likely redesign or re-certification. |
| UFGS 44 11 00 | IEC 61511 | NDT methods | Similar | Low | Requirements broadly equivalent; document equivalency in design analysis. |
| UFC 3-401-01 | IEC 60079-14 | Hydrotest | Partial | Medium | Partial alignment; supplemental U.S. testing or documentation required. |
| NFPA 15 | 2014/34/EU | Leak testing | Partial | Low | Partial alignment; supplemental U.S. testing or documentation required. |
| UFC 3-600-01 | DIN EN 1127-1 | SIL calculation | Significant Difference | High | Fundamental differences; requires AHJ/NRTL review and likely redesign or re-certification. |
| UFC 3-575-01 | DIN EN ISO 13849-1 | Alarm management | Similar | Low | Requirements broadly equivalent; document equivalency in design analysis. |
| UFGS 21 30 00 | EN 1993 | Emergency lighting | Partial | Medium | Partial alignment; supplemental U.S. testing or documentation required. |
| DESR 6055.09 | UK ER 2014 | Explosives separation distances | Significant Difference | High | UK uses HSE separation tables by hazard type; apply the more restrictive distance per exposure and document both. |
| DESR 6055.09 | SprengG | Explosives licensing and storage | Partial | High | German storage groups map loosely to HD; host-nation licensing is required in addition to DDESB site plan. |
| DESR 6055.09 | 2. SprengV | Storage separation distances | Partial | High | Compare Lagergruppe distances to DESR QD; use larger value. |
| NIST SP 800-82 Rev 3 | IEC 62443-3-3 | Control system cybersecurity | Similar | Low | Map NIST controls to 62443 SRs; target SL2 minimum for SIS networks. |
| UFC 4-010-06 | IEC 62443-3-3 | Facility control system security | Partial | Medium | UFC requires DoD RMF authorization; 62443 certification alone does not satisfy ATO. |
| 40 CFR 70 | 2010/75/EU | Air emissions permitting | Partial | Medium | IED requires BAT conclusions; Title V does not. Prepare BAT assessment for EU sites. |
| 29 CFR 1910.119 | 2012/18/EU | Major hazard / process safety | Partial | Medium | Seveso requires public safety report and land-use planning beyond PSM. |