FOW-STO-033Critical

Energetic Material Storage – Building 100

Energetic Material Storage – Building 100: design, construction and commissioning within a defense energetics production facility.

Most Restrictive Requirement
UFC 4-420-01

DoD 6055.09 QD arcs and UFC 4-420-01 magazine criteria govern siting and construction.

Design Criteria

Hazard Division
1.4
UFC 4-420-01 Table 3-1
Max Net Explosive Weight
5000 lb NEW
UFC 4-420-01 Para. 4.2
Inhabited Building Distance
1800 ft
UFC 4-420-01 Table 8-9
Hazardous Area Classification
Unclassified
UFC 4-420-01 Art. 500/505
Required SIL
SIL 3
UFC 4-420-01 IEC 61511 §9
Sprinkler / Deluge Density
0.50 gpm/ft²

Illustrative values — confirm against the cited edition before design use.

Summary

Discipline
Explosives Safety
Category
Storage
Risk Level
Critical
Approval Authority
Army Explosives Safety Office
Standards Applied
14 across 8 families
Verified Links
3 of 14 approved
Common Equipment
Blast Resistant Door, Intrusion Detection Sensor, Access Control Panel, UV/IR Flame Detector

Applicable Standards (14)

Structural
Explosives Safety
Fire Protection
Process Safety
Security

Governing Authorities

  • Army Explosives Safety Office
    Explosives Safety Authority · Site plans, QD arcs, explosives safety submissions
    Lead
  • DDESB
    DoD Explosives Safety Board · Explosives safety site plan approval
  • Security Authority
    Installation Security / AT-FP · Anti-terrorism, access control, physical security

Highest Risk Items

  • Insufficient QD separationCritical
    Remote operation, shielding per UFC 3-340-02, and explosives safety review prior to start-up.
  • Blast door failureHigh
    Engineering controls, third-party verification and AHJ acceptance testing.

Known U.S. / European Conflicts (9)

DESR 6055.09↔UK ER 2014· Explosives separation distancesSignificant Difference
UK uses HSE separation tables by hazard type; apply the more restrictive distance per exposure and document both.
DESR 6055.09↔SprengG· Explosives licensing and storagePartial
German storage groups map loosely to HD; host-nation licensing is required in addition to DDESB site plan.
DESR 6055.09↔2. SprengV· Storage separation distancesPartial
Compare Lagergruppe distances to DESR QD; use larger value.
29 CFR 1910.119↔2012/18/EU· Major hazard / process safetyPartial
Seveso requires public safety report and land-use planning beyond PSM.
NFPA 68↔DIN EN 14491· Dust explosion ventingPartial
Partial alignment; supplemental U.S. testing or documentation required.
NFPA 72↔DIN EN 54· Fire detectionPartial
Partial alignment; supplemental U.S. testing or documentation required.
UFC 3-310-04↔EN 1998· Seismic designPartial
Partial alignment; supplemental U.S. testing or documentation required.
UFGS 21 13 18↔2014/34/EU· Cable sizingPartial
Partial alignment; supplemental U.S. testing or documentation required.
NFPA 68↔2014/34/EU· Smoke controlPartial
Partial alignment; supplemental U.S. testing or documentation required.