← Equipment
Structural · Compliance Report
Blast Resistant Door
Blast Resistant Door used in energetics production and support facilities.
Most Restrictive Requirement
EN 1990
Basis of Structural Design
Required Certifications
- UFC 3-340-02 Blast Test
- ASTM F2927 Rating
- GSA Blast Certification
Typically Missing at Submittal
- ASTM F2927 Rating
- DoD RMF ATO
Known Issues
- Static dissipative materials not validated for energetic dust
- IEC terminal identification differs from NEC color code
Required Standards (4)
- EurocodeEN 1990Basis of Structural Design
- EurocodeEN 1993Design of Steel Structures (Eurocode 3)
- UFGSUFGS 03 30 00Cast-in-Place Concrete
- UFGSUFGS 08 56 53Blast Resistant Windows
Approval Authorities
- AHJAuthority Having Jurisdiction
- Cybersecurity Authority (ISSM)RMF Authorizing Official
Used in Features of Work
- Energetic Material Storage – Line ACritical
- Energetic Material Storage – Building 100Critical
- Control Room – Building 200Critical
- Control RoomCritical
- Blast Resistant Structure – Line ACritical
- Blast Resistant Structure – Building 100Critical