← Equipment
Environmental · Compliance Report
Wet Scrubber
Wet Scrubber used in energetics production and support facilities.
Most Restrictive Requirement
40 CFR 264
RCRA Hazardous Waste TSD Facilities
Required Certifications
- EPA Performance Test
- NRTL Listing
- Air Permit Conformance
Typically Missing at Submittal
- Air Permit Conformance
- UL 508A
Known Issues
- IEC terminal identification differs from NEC color code
- CE-marked vessel lacks ASME U-stamp
Required Standards (4)
- EPA40 CFR 264RCRA Hazardous Waste TSD Facilities
- EPA40 CFR 60New Source Performance Standards
- VDIVDI 3783Environmental Meteorology - Dispersion
- UFGSUFGS 44 11 00Particulate Control Equipment
Approval Authorities
- USACEConstruction Agent / Design Review
- Fire Protection EngineerQualified Fire Protection Engineer
- Pressure Equipment InspectorNational Board Commissioned Inspector
Used in Features of Work
- Hazardous Ventilation – Building 200High
- Hazardous VentilationHigh
- Dust Collection – Line AHigh
- Dust Collection – Building 100Low
- Open Burn / Open Detonation – Building 200Medium
- Open Burn / Open DetonationMedium
- Air Emissions Control – Line AHigh
- Air Emissions Control – Building 100Medium
- Wastewater Treatment – Building 200Low
- Wastewater TreatmentMedium