← Feature Explorer
FOW-STR-106High
Barricades & Earth-Covered Magazines
Earthen barricades and earth-covered magazines for in-process and bulk storage.
Summary
- Discipline
- Structural
- Category
- Structural
- Risk Level
- High
- Approval Authority
- DDESB
- Standards Applied
- 4 across 3 families
- Verified Links
- 0 of 4 approved
- Common Equipment
- —
Applicable Standards (4)
Structural
- UFCUFC 3-340-02DraftStructures to Resist the Effects of Accidental Explosions
Explosives Safety
- DoDDESR 6055.09governsDraftDoD Explosives Safety Regulation (Volumes 1–8)
- DoDDDESB TP 15DraftApproved Protective Construction
Electrical
- NFPANFPA 780DraftInstallation of Lightning Protection Systems
Governing Authorities
- DDESBDoD Explosives Safety Board · Explosives safety site plan approval
Highest Risk Items
Known U.S. / European Conflicts (5)
DESR 6055.09↔UK ER 2014· Explosives separation distancesSignificant Difference
UK uses HSE separation tables by hazard type; apply the more restrictive distance per exposure and document both.
DESR 6055.09↔SprengG· Explosives licensing and storagePartial
German storage groups map loosely to HD; host-nation licensing is required in addition to DDESB site plan.
DESR 6055.09↔2. SprengV· Storage separation distancesPartial
Compare Lagergruppe distances to DESR QD; use larger value.
UFC 3-340-02↔EN 1991-1-7· Accidental explosion loadsSignificant Difference
Fundamental differences; requires AHJ/NRTL review and likely redesign or re-certification.
NFPA 780↔DIN EN 62305· Lightning protectionPartial
Partial alignment; supplemental U.S. testing or documentation required.