← Equipment
Structural · Compliance Report
Blast Resistant Window
Blast Resistant Window used in energetics production and support facilities.
Most Restrictive Requirement
UFC 3-340-02
Structures to Resist the Effects of Accidental Explosions
Required Certifications
- UFC 3-340-02 Blast Test
- ASTM F2927 Rating
- GSA Blast Certification
Typically Missing at Submittal
- GSA Blast Certification
- NRTL Listing
Known Issues
- Missing FM approval for explosion vent
- Static dissipative materials not validated for energetic dust
Required Standards (5)
- UFCUFC 3-340-02Structures to Resist the Effects of Accidental Explosions
- UFCUFC 3-301-01Structural Engineering
- UFGSUFGS 13 34 19Metal Building Systems
- EurocodeEN 1992Design of Concrete Structures
- UFGSUFGS 08 34 63Blast Resistant Doors
Approval Authorities
- USACEConstruction Agent / Design Review
- Fire Protection EngineerQualified Fire Protection Engineer
- Pressure Equipment InspectorNational Board Commissioned Inspector